Common array manager.

Common Array Manager. user-lvozg Feb 12 2023. Unable to see StorageTek6410 in Oracle Java Web Console after installing Common Array Manager, but I can only see Hosts statistics such as cpu usage, local hard drive and memory usage status.

Common array manager. Things To Know About Common array manager.

To Assign an IP Address to Each Ethernet Port. . Access the Sun StorageTek Common Array Manager software: Open a web browser and enter the IP address of the management host: https://management-host:6789. management-host is the IP address of the machine where you installed the management software. The Sun StorageTek Common Array Manager software provides you with an easy-to-use interface to configure, manage, and monitor Sun StorageTek storage arrays. New features in Release 6.0.0: Enhancements to Auto Service Request (ASR) functionality. Support for Sun StorageTek FLX240, FLX280, and FLX380 Arrays.Jun 4, 2023 · This article documents Sun Storage 6140 Array's components firmware baseline bundled in each corresponding CAM release and patched versions. This document assumes the relevant array product is managed with Common Array Manager. This reference can be used by end-user and all levels of support personnel for purpose of verifying component firmware ... Storage Common Array Manager 6.8.1. Sun Storage 2500-M2 Arrays and StorageTek 2500 Series Arrays Sun Storage 6000 Series, StorageTek 6000 Series, and FlexLine Arrays Sun Storage J4000 Series Arrays, Sun Storage F5100 Flash Array, and Sun Blade 6000 Disk Module Sun Storage 2500-M2 Arrays and StorageTek 2500 Series Arrays1

Note: The sscs command has an 30 minute inactivity timer before you are logged out. cd /opt/SUNWsesscs/cli/bin/. sscs login -u storage|guest -h host-name [-f] [-t] The following list describes the short and long name command options for the login command: -u, --username. Default user names are storage and guest. Select Sun Storage Common Array Manager Software 6.10, and download the software. For detailed MOS download steps, see the knowledge article “How to Download Common Array Manager (CAM) Software and Patches” Doc ID 1296274.1 available on MOS. Note - Each array should be managed by one CAM management host only.To use the Sun Storage Common Array Manager, users and roles must be defined on the host and assigned in the array management software. Make sure the following user names are defined on your systems: root (or an administrative user for Windows) storage; guest; User names must be a currently defined user on the management host.

Sun Storage Common Array Manager supports these arrays: Sun Storage 6000 array series. StorageTek 2500 array series. StorageTek FlexLine array series. Sun Storage …

viSun StorageTek Common Array Manager 软件安装指南• 2008 年 10 月. 查找文件和日志 11 安装命令汇总 13 从远程终端安装(Solaris 和 Linux) 13 在 Solaris OS 上安装 14 在 Solaris OS 上使用 GUI 进行安装 14. 安装软件(在 Solaris 系统上):15 在 Solaris OS 上使用 CLI 进行安装 19. 使用 ... This guide can help you with the basic steps of installing Oracle’s Sun Storage Common Array Manager software. If you are upgrading from a previous version or need additional information, see theSun Storage Common Array Manager Software Installation and Setup Guide. See Documentation, Support, and Training forStorage Common Array Manager 6.10. Sun Storage 2500-M2 Arrays and StorageTek 2500 Series Arrays Sun Storage 6000 Series, StorageTek 6000 Series, and FlexLine Arrays Sun Storage J4000 Series Arrays, Sun Storage F5100 Flash Array, and Sun Blade 6000 Disk Module Sun Storage 2500-M2 Arrays and StorageTek 2500 Series Arrays1Category filter: Show All (183)Most Common (3)Technology (42)Government & Military (46)Science & Medicine (41)Business (40)Organizations (52)Slang / Jargon (5) Acronym Definition CAM Camera CAM Computer-Aided Manufacturing CAM Camshaft CAM 7 CAM Camcorder (video source) CAM Complementary and Alternative Medicine CAM Camden …

Select Sun Storage Common Array Manager Software 6.10, and download the software. For detailed MOS download steps, see the knowledge article “How to Download Common Array Manager (CAM) Software and Patches” Doc ID 1296274.1 available on MOS. Note - Each array should be managed by one CAM management host only.

Note - At the release of this document, there is currently no support for using the Common Array Manager to upgrade disk module and SAS-NEM firmware to a level that allows SAS-1 device coexistence with server modules with SAS-2 REMs.For more information on upgrading disk module and SAS-NEM firmware to a level that allows SAS-1/SAS-2 …

1. On the local terminal, enter the following to enable display from the Common Array Manager host: $ xhost + 2. Telnet to the Common Array Manager host (where the Common Array Manager Installation CD or download file is located, and where the Common Array Manager will be installed): telnet x.x.x.x. 3. After logging in, switch user to root: $ su - Learn how to use the command line interface (CLI) to manage your Sun StorageTek Common Array Manager (CAM) arrays. This quick reference guide provides the syntax and examples of the most common CLI commands.Sun Storage Common Array Manager software models the aggregated connections as a single, logical SAS port. The information displayed in the Access Configuration Summary only lists the connected port with the higher alphanumeric sort. For example, if Ports 0 and 2 are connected into the same expander, only Port 2 is listed. Sun Storage Common Array Manager does not provide an SNMP agent that can be queried using SNMP ’GET’ operations. At times, the devices themselves support SNMP ’GET’ operations although all the arrays supported by the array management software at this time do not. Look for the StorageTek Common Array Manager (CAM) Software release 6.1.2 or later. Using CAM With Disk Blades and Virtualized Multi-Fabric 10GbE NEM. CAM provides both a browser and command-line interface. When using the browser interface, you set up user accounts. When an authorized user logs in, information is laid out in pages. The Sun StorageTek Common Array Manager provides a browser interface for accessing the management software from any host that is connected to the site LAN. The web-based browser interface is the primary interface for configuring, managing, and monitoring the system. Applying Solaris patch 147416-02 (sparc) or patch 147419-02 (x86) to Sun Storage Common Array Manager (CAM) version 6.9.0 may cause registered arrays to present an alarm stating that out-of-band (oob) communication has been lost, and report the health status of the array as "Lost Communication"

It is best practice to upgrade HBAs (SG-XPCIE8SAS-E-Z) to Phase 14 firmware (1.26.03 or later) before upgrading JBOD installations to Sun Storage Common Array Manager version 6.6 and above. This helps avoid issues when discovering JBODs that have SIM firmware 3A53 (J4200) or 3R53 (J4400).Sun StorageTek Array Administration Guide For Sun StorageTek Common Array Manager, Release 6.2: PDF: Sun StorageTek Common Array Manager CLI Guide, Release 6.2.0: HTML: PDF: Sun StorageTek Common Array Manager CLI Guide for the J4000 Array Family: HTML: PDF: Sun StorageTek Common Array Manager User …The Sun Storage Common Array Manager CLI Guide, Version 6.9.0, describes the commands in the sscs command-line interface (CLI) for Oracle's storage arrays. Review the latest array baseline firmware versions delivered with Oracle's Sun Storage Common …This article documents Sun Storage 6580/6780 Array's components firmware baseline bundled in each corresponding CAM release and patched versions. This document assumes the relevant array product is managed with Common Array Manager. This reference can be used by end-user and all levels of support personnel for purpose …This document assumes the relevant array product is managed with Common Array Manager. This reference can be used by end-user and all levels of …Sun Storage 2530-M2 Array - Version Not Applicable and later All Platforms Goal. This document describes the significance of a volume's "owning controller" and "preferred controller", and also explains how to change the "owning controller" setting of an individual volume via the Sun Storage Common Array Manager software.

1. On the local terminal, enter the following to enable display from the Common Array Manager host: $ xhost + 2. Telnet to the Common Array Manager host (where the Common Array Manager Installation CD or download file is located, and where the Common Array Manager will be installed): telnet x.x.x.x. 3. After logging in, switch user to root: $ su -

Storage Common Array Manager 6.8.1. Sun Storage 2500-M2 Arrays and StorageTek 2500 Series Arrays Sun Storage 6000 Series, StorageTek 6000 Series, and FlexLine Arrays Sun Storage J4000 Series Arrays, Sun Storage F5100 Flash Array, and Sun Blade 6000 Disk Module Sun Storage 2500-M2 Arrays and StorageTek 2500 Series Arrays1Common Array Manager. 895784 Oct 22 2011 — edited Oct 22 2011. Hi Experts, I am Installing Common array manager software on sparc T5120, while installing sun java web console is missing some LION packages whether i go forward what will happen? any solution for this please guide me. Thanks, kk. Comments.Sun Storage 2530-M2 Array - Version Not Applicable and later: Sun StorageTek[TM] Common Array Manager Software: Enabling Automatic Service Request Generation ... is a feature of the array management software that monitors the array system health and automatically notifies Oracle when critical events occur. Critical alarms generate a … The Sun Storage Common Array Manager (CAM) 6.10 Update release is available only for Solaris OS management hosts. Oracle’s Sun Storage Common Array Manager (CAM) 6.10 software that includes the fix for the following CVEs is supported only on Oracle Solaris 10 SPARC and x86 platforms. If you are running the CAM software on Windows or Linux ... The SAS expander on the Virtualized Multi-Fabric 10GbE NEM is SES-2 compliant. These enclosure management features are available through the management software called the Sun Common Array Manager (CAM), which provides a system administrator with the following capabilities: Event and fault monitoring. E-mail alert notification Sun Storage Common Array Manager Software Release Notes, Release 6.9.0 Update December 2012. Review important late-breaking information about Sun Storage Common Array Manager.Common Array Manager May be Solaris forum is not the best choice for asking such question, but I really need help with SunStorage FC array. AFAIK this array can be configured only with CAM software by Sun, but sadly all previously free Metalink downloads are now accessible only as a part of paid support (and I have no idea why we …Support data for an array is collected and saved in the Common Array Manager by selecting array > General Configuration > Support Data. On the Windows 2008 server, disable “Do not save encrypted pages to disk.” Go to Tools > Internet Options > Advanced > Security and uncheck "Do not save encrypted pages to disk." Linux platformsApr 3, 2023 · Sun Storage Common Array Manager (CAM) has the ability to collect support-based configuration and logs for Sun Storage 2500, 2500-M2, J4000, F5100, 6000 and Flexline Arrays. This can be performed using the Browser or CLI interface. The purpose of this document is to describe how to collect this information. If you are using a Sun Storage J4000 ... Select Sun Storage Common Array Manager Software 6.10, and download the software. For detailed MOS download steps, see the knowledge article “How to Download Common Array Manager (CAM) Software and Patches” Doc ID 1296274.1 available on MOS. Note - Each array should be managed by one CAM management host only.

1. On the local terminal, enter the following to enable display from the Common Array Manager host: $ xhost + 2. Telnet to the Common Array Manager host (where the Common Array Manager Installation CD or download file is located, and where the Common Array Manager will be installed): telnet x.x.x.x. 3. After logging in, switch user …

The Sun StorageTek[TM] Common Array Manager (CAM) has the ability to collect support based configuration and logs for Sun StorEdge[TM], Sun StorageTek [TM], StorageTek[TM], Sun Storage[TM] Arrays. This can be performed using the Browser or CLI interface. The purpose of this document is to describe how to collect this information.

Sun Storage Common Array Manager software models the aggregated connections as a single, logical SAS port. The information displayed in the Access Configuration Summary only lists the connected port with the higher alphanumeric sort. For example, if Ports 0 and 2 are connected into the same expander, only Port 2 is listed.2 Sun Storage Common Array Manager Software 6.8.1 Release Notes • September 2011 About the Software Sun Storage Common Array Manager software provides an easy-to-use interface from which you can configure, manage, and monitor storage arrays. The software includes a distributed architecture enabling you to designate local and You’ll find the most current information about Sun StorageTek Common Array Manager software in these 6.1.1 version Release Notes, including features, release ... Sun StorageTek Array Administration Guide, Version 6.5.0. PDF. Sun StorageTek Common Array Manager User Guide for Open Systems. HTML. PDF. Sun StorageTek Common Array Manager CLI Guide, Version 6.5.0. HTML. PDF. Sun StorageTek Common Array Manager Software 6.5 Product Library Documentation. 通过打开浏览器并输入下列地址,从主阵列管理服务器登录 Sun Storage Common Array Manager: https://host-name:6789. 其中,host-name 为连接到该阵列的服务器的 DNS 名称。. 在“存储系统摘要”页面中,单击“注册”并按照向导中的说明将该阵列注册到第一个服务器的 IP 地址 ... “Related Documentation” on page vi for a list of array installation document titles. Related Documentation TABLE P-1 provides a list of documents related to the Sun Storage Common Array Manager software. TABLE P-1 Related Documentation Application Title Latest information Sun Storage Common Array Manager Software Release Notes Chapter 1 Sun Storage Common Array Manager Software Release Notes. Use this document for instructions about how to download the latest Oracle's Sun Storage Common Array Manager software and learn about new features, related documentation, system requirements, notable bug fixes, and known issues for the CAM 6.9.0 product release.The Sun StorageTek Common Array Manager CLI Guide describes the commands in the sscsCLI. Consult the hardware installation guide for your array for information about the initial physical installation of an array. Related Documentation In addition, the Sun StorageTek Common Array Manager includes the following online documentation:The Sun StorageTek[TM] Common Array Manager (CAM) has the ability to collect support based configuration and logs for Sun StorEdge[TM], Sun StorageTek [TM], StorageTek[TM], Sun Storage[TM] Arrays. This can be performed using the Browser or CLI interface. The purpose of this document is to describe how to collect this information.

iv Sun StorageTek Common Array Manager CLI Guide • September 2009 Commands Used 21 Sample Data 21 Command Sequence 21 3. Monitoring and Administration Commands for All Arrays 27 add notification 27 Synopsis 27 Description 28 Options 28 Examples 29 add registeredarray 29 Synopsis 29 Description 29 Options 30 Examples 30Sun StorageTek Common Array Manager CLI Guide sscs man pages. Preface xiv Third-Party Web Sites Sun is not responsible for the availability of third-party web sites mentioned in this document. Sun does not endorse and is not responsible or liable for any content,1. On the local terminal, enter the following to enable display from the Common Array Manager host: $ xhost + 2. Telnet to the Common Array Manager host (where the Common Array Manager Installation CD or download file is located, and where the Common Array Manager will be installed): telnet n.n.n.n. 3. After logging in, switch user …Mar 9, 2022 · Goal. Sun Storage Common Array Manager (CAM) has two main services: Java Web Console (JWC) and Fault Management Service (FMS). Generally starting and stopping the JWC service is done when troubleshooting login problems, making JWC configuration changes, installing a JWC patch, or installing a legacy JWC application. Instagram:https://instagram. free jewel quest gamesgantt chart in google sheetsquicker mathematicshoodwinked full movie Goal. This article documents Sun Storage 2540-M2 Array's components firmware baseline bundled in each corresponding CAM release and patched versions. … zenless zone zeror player Most people looking for Common array manager downloaded: Sun Storage Common Array Manager Online Help. Download. One Interface, Run-Anywhere Flexibility Now there's an easy way to manage your storage environment. Similar choice › Download common view exe free › Gnu common lisp 2.4.9 free download;This document describes a possible problem in Sun Storage Common Array Manager (CAM) version 6.9.0.20 on Solaris that can prevent registration of arrays. CAM 6.9.0.20 involves the installation of CAM 6.9 and then the addition of either <Patch 147416-02> (Solaris SPARC) or <Patch 147419-02> (Solaris x86). Array registration in … turkish language to english The Sun StorageTek Common Array Manager CLI Guide for Release 6.2 describes the commands in the sscs CLI. Sun StorageTek Common Array Manager CLI Guide, Release 6.2.0 C H A P T E R 1: Overview This chapter provides an overview of the sscs administration command for Sun StorageTek and Sun Storage arrays. It contains the … OUTPUT. Sun Storage Common Array Manager Software Release Notes Release 6.10 for Solaris OS Host l. Review important late-breaking information about Sun Storage Common Array Manager 6.10. Download. Sun Storage Common Array Manager Version: 6.10.0 Third Party License README l. This Third Party License README document applies to Sun Storage ...